| Separate the Motor from the
Bearing Assembly Support the motor
assembly before beginning this procedure. Use a box wrench to loosen and remove the four
motor cap screws connecting the motor to the bearing assembly.
With the cap screws removed, the motor can be
separated from the bearing assembly. provided that the coupler set screws were backed off
sufficiently, the coupler should slide free of the pump shaft. If tight, a screwdriver may
be used to gently pry the coupler loose. |