| Proper Oiling Procedures Most misalignment problems can be attributed to
motor mounts that begin to sag. Such sagging will lead to coupler fatigue and ultimately
to failure. The life of motor mounts can be significantly increased if proper oiling
procedures are followed. When motors receive excessive oil, the spill-over can saturate
and soften the mounts neoprene material; over oiling can also cause spillage onto
surrounding surfaces.
Bell & Gossett recommends that the pump bearings be lubricated with ½ teaspoon (20
to 30 drops) of B&G 20# weight non-detergent oil at the start of each heating season.
A SAE 20 oil or 10W-30 oil may be substituted if B&G oil is not available.
Motor bearings should be lubricated as instructed on the lubrication decal once every
four months (more often under adverse conditions). Use eight to ten drops in each oil
tube. |