House Tour
Snow Melting Loop
 

BOILER
A boiler is a closed vessel in which water or other fluid is heated under pressure. The heated water is circulated though out the system to provide space heating, pool heating, hot domestic potable water heating, etc.

GUARD DOG LOW WATER CUT-OFF
A low water cut-off does two things. First, it accurately detects a low water condition should it occur. Second, it automatically shuts down the combustion operation of the boiler. This will prevent the boiler from firing while its water level is too low to properly manage the heat and energy. A low water cut-off is required by code in many states in the USA and many boiler manufacturers stipulate that cut-offs are to be routinely installed, especially if radiation is installed below the level of the boiler.

POWERPURGE ISOLATION VALVE and DRAIN
PowerPurge Isolation Valve eliminates air from the system.

EASB-JR AIR SEPARATOR
EASB-JR Air Separator is designed to automatically remove entrained air bubbles in hydronic systems. As fluid enters the air separator, the velocity is decreased creating a low-pressure area. The small bubbles are released from fluid and then collect on the coalescing medium. As the bubbles coalesce, they rise to the top of the air separator where they are released to atmosphere through the built-in automatic air vent.

HFT DIAPHRAGM TANK
HFT Diaphragm Tank is used to absorb the force of thermal expansion on the boiler loop when the closed loop boiler system water is increased and to maintain proper pressurization.

ASME SAFETY RELIEF VALVE
B&G diaphragm operated cast iron and diaphragm-assist operated bronze ASME Safety Relief Valves are designed to protect fired and unfired hot water pressure vessels against over-pressure conditions.

PRIMARY CIRCULATOR PUMP
Moves hot water from the boiler to the radiation.

PRESSURE REDUCING VALVE
B&G reducing valves protect heating and plumbing systems against excessive line pressures.

BPX BRAZED PLATE HEAT EXCHANGER
BPX Brazed Plate Heat Exchanger heats the glycol/water mix used in the snow melt system using the boiler water as the heat source. BPX separates the boiler water from the snow melt water into two independant piping loops. The boiler water and snow melt fluid pass through separate plates in the BPX providing maximum heat transfer while never coming in contact.

PRIMARY SNOW MELT CIRCULATOR
Primary Snow Melt Circulator circulates the snow melt glycol through heat exchanger

HFT DIAPHRAGM TANK
HFT Diaphragm Tank is used to absorb the force of thermal expansion on the snow melt loop when the closed loop snow melt system glycol/water mix is increased and to maintain proper pressurization.

SNOW MELT CIRCULATOR
Snow Melt Circulator circulates the water/glycol mix through the buried tubing in the snow melt system.

EASB-JR AIR SEPARATOR
EASB-JR Air Separator removes entrained air including micro-bubbles in the snow melt loop making system more efficient, operate quieter and last longer.

COMFORT-TROL™ ZONE CONTROL VALVE
Another way to zone a hot water system is to use electric zone valves. The zone valve takes the place of the Flo-Control valve. Each zone valve acts as a "Gatekeeper" to the zone it serves. The circulator provides the water, and the zone valve allows that water to either pass or not pass.

Y-STRAINER
Y- Strainer collects dirt and debris in the system to protect the other components in the system.