| Elastomeric couplings
are specifically designed to accommodate angular shaft misalignment, as well as parallel
offset of the pump and motor shafts. However, the amount of the offset and/or misalignment
is dependent on the type and style of flexible coupling applied. Left unchecked, coupling
misalignment has a significant impact on the overall life of the mechanical seals and
bearings of the pump. |
|
| Coupling Type |
VSX Non-spacer coupling up to 1000 HP @1750 RPM |
Jaw Type |
EPDM |
Hytrel |
| Angular Misalignment
|
2 - 4 Degrees |
.9 1.3 Degrees |
1 Degree |
.25 Degrees |
| Parallel Misalignment
|
1/16 1/8 |
.008 - .027 |
.01 - .062 |
.01 - .035 |
|
|